Idex-health-science MCP-Z Process Manuel d'utilisateur Page 34

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 60
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 33
34
MCP-Z Process / ISMATEC SA / 03.08.07/CB/GP
Digitale Eingänge (TTL-Pegel)
Digital inputs (TTL-level)
Entrées numériques (niveau TTL)
Pin 2, remote
Pin 3, start
Pin 6, input 1
Pin 8, input 2
Pin 13, speed intern
Analoge Eingänge
Analog inputs
Entrées analogiques
Pin 5, speed IN
0 – 5 V
DC
/ 0 – 10 V
DC
0 – 20 mA / 4 – 20 mA
Universal Ausgänge (PWM)
Universal outputs (PWM)
Sorties universelles (PWM)
Pin 14, output 1
Pin 15, output 2
Analoge Ausgänge
Analog outputs
Sorties analogiques
Pin 9, speed OUT
0 – 10 V
DC
/ 0 – 12 kHz
8 7 6 5 4 3 2 1
15 14 13 12 11 10
9
speed IN direction
input 1 start
+26VDC remote
input 2 GND
output 2 speed OUT
output 1 +5VDC
speed intern
+39VDC
Analogschnittstelle
Pin 9, speed OUT
Die werkseitige Einstellung ist
0 –10 V
DC
, proportional zur Motor-
drehzahl 0 – 6000 min
–1
.
Alternativ steht ein Frequenz-
bereich von 0 – 12 kHz zur Ver-
fügung. Wahlmöglichkeit mittels
Schiebeschalter S2 im Gerätein-
nern (siehe Seite 35)
Pin 10, +5 V
DC
Es stehen ca. +5 V
DC
zur Verfü-
gung. (max. Strom 0.5 A)
Pin 13, speed intern
Abhängig von der Betriebsart hat
Pin 13 unterschiedliche Funktio-
nen:
Analogschnittstelle nicht aktiviert
(Normalbetrieb, d.h. Pin 2 offen)
Hier dient Pin 13 als Autostart-
funktion. Ist Pin 13 mit Pin 1
(GND) verbunden, kann die Pum-
pe direkt über die Netzspannung
gestartet bzw. angehalten werden
(Netzschalter muss eingeschaltet
sein).
Analogschnittstelle aktiviert
(Pin 2 auf GND)
- Pin 13 offen:
Die Drehzahl wird über Pin 5
(speed IN) vorgegeben.
- Pin 13 auf GND
Die Drehzahl kann am Bedie-
nungspanel der Pumpe einge-
stellt werden.
Pin 14, output 1 (PWM)
Pin 15, output 2 (PWM)
Digitale Ausgänge in Verbin-
dung mit Pin 7 (+39 V
DC
), als
Pulsweiten-Modulation ausge-
führt (Open Collector). Können
nur über RS232-Schnittstelle be-
dient werden; z.B. mit einer Soft-
ware wie ProgEdit .
Analog interface
Pin 9, speed OUT
The default setting is 0 –10 V
DC
,
proportionally to the motor speed
0 – 6000 rpm.
Alternatively a frequency range
from 0 – 12 kHz is available. Al-
ternatives with sliding switch S2
inside the pump (see page 35)
Pin 10, +5 V
DC
About +5 V
DC
are available.
(max. current 0.5 A)
Pin 13, speed intern
Depending on how the pump is
operated, pin 13 has different
functions:
Analog interface not activated
(Normal operation, i.e. pin 2 is
open) Pin 13 serves as auto-start
function. If pin 13 is connected
to pin 1 (GND), the pump can be
started and stopped directly from
the power supply (the power
switch must be on).
Analog interface activated
(Pin 2 on GND)
- Pin 13 open:
The rotation speed is adjusted
via pin 5 (speed IN).
- Pin 13 on GND:
The rotation speed can be ad-
justed by the speed selector on
the control panel of the pump.
Pin 14, output 1 (PWM)
Pin 15, output 2 (PWM)
Digital outputs in connection with
pin 7 (+39 V
DC
), implemen-ted as
pulse-width-modulation (open
collector). Can only be activated
via RS232 interface, e.g. with a
software like the ProgEdit.
Interface analogique
Pin 9, speed OUT
Le réglage d’usine par défaut est
0 –10 V
CC
, proportionnel au nombre
de tours du moteur 0 – 6000 t/min.
Une zone de fréquence de 0 – 12
kHz est à disposition en alternative.
Possibilité de sélection au moyen
d’un interrupteur coulissant S2 à
l’intérieur de l’appareil (v.p. 35).
Pin 10, +5 V
CC
Environ +5 V
CC
sont à disposition
(courant maximal 0.5 A)
Pin 13, speed intern
Le pin 13 possède des fonctions
différentes en fonction du mode
d’opération:
Interface analogique non activée
(Mode d’opération normal, c.-à-d.
pin 2 ouvert) Le pin 13 a la fonc-
tion „auto-start“. Si le pin 13 est
connecté au pin 1 (GND), la pompe
peut être mise en service ou arrêtée
directement par l’alimentation élec-
trique (l’interrupteur principal doit
être sur ON).
Interface analogique activée
(Pin 2 sur GND)
- Pin 13 ouvert: La vitesse de rota
tion doit être ajustée par le pin
5 (speed IN).
- Pin 13 sur GND: La vitesse de
rotation peut être ajustée par le
sélecteur de vitesse sur le tab-
leau de commande de la pompe.
Pin 14, output 1 (MLI)
Pin 15, output 2 (MLI)
Sorties numériques en relation
avec le pin 7 (+39 V
CC
), mis en
œuvre comme modulation de
largeur d'impulsion (collecteur
ouvert). Ne peuvent être activées
que par le biais de l’interface RS232,
p.e. avec le logiciel ProgEdit.
Vue de la page 33